Availability: | |
---|---|
Quantity: | |
CNME100101-A
CNMEDITECH
Laboratory Blood Sample Test Vacuum Blood Collection Tube
The Vacuum Blood Collection Tube is a sterile, pre-evacuated container designed for the direct collection of blood samples. Utilizing controlled negative pressure, it enables the automatic draw of a precise blood volume, ensuring standardized sample collection for a wide range of clinical laboratory tests.
Structure and Components:
Tube Body: Manufactured from durable, medical-grade materials such as polyethylene terephthalate (PET), offering excellent chemical resistance and sample visibility.
Pre-set Vacuum: The tube is pre-filled with a specific vacuum pressure to draw the exact required volume of blood.
Color-coded Stopper/Cap: The rubber stopper is color-coded to indicate the presence and type of additive (e.g., EDTA, citrate, heparin, clot activator) and the tube’s intended use.
Additives (Optional): Tubes may contain anticoagulants, clot activators, serum separators, or no additives, depending on the test requirements.
Label: Clearly printed for patient identification, additive details, and compatibility with barcode systems.
Features:
Accurate volume collection: Ensures consistent and reliable blood volumes.
Sterile and single-use: Minimizes risk of cross-contamination.
Color-coded caps: Easy identification of tube type and corresponding laboratory test.
Leak-proof design: Guarantees safe sample handling and transport.
Available with different additives: To support diverse testing needs, including coagulation, chemistry, hematology, serology, and molecular diagnostics.
Specifications:
Model/Name | Size | Color | Additives | |||
CNME100101-1A | Plain Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Red | NO |
CNME100101-2A | Clot Activator Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Red | Clot Activator |
CNME100101-3A | Heparin Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Green | Sodium/Heparin lithium |
CNME100101-4A | Gel&clot Activator Tube | 1-4ml (13*75mm) | 4-6ml (13* 100mm) | 6-9ml (16*100mm) | Yellow | Gel&clot Activator |
CNME100101-5A | Glucose Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Grey | EDTA+Sodium Fluoride |
CNME100101-6A | EDTA Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Purple | EDTA K2(K3/Na2) |
CNME100101-7A | ESR Tube | 1-5ml (13*75mm) | / | / | Black | 3.8%Sodium Citrate |
CNME100101-8A | PT Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Blue | 3.2% Sodium Citrate |
Advantages:
Efficient and fast collection: No need for syringe transfer; reduces collection time and minimizes sample handling errors.
Standardized sampling: Pre-calibrated vacuum ensures consistency across samples.
Improves workflow: Supports high-throughput environments like hospitals, clinics, and diagnostic labs.
Enhanced safety: Closed system reduces the risk of exposure to bloodborne pathogens.
Wide compatibility: Suitable for use with standard phlebotomy systems, such as multi-sample needles and holders.
Usage Instructions:
Assemble the collection device (needle, holder, and vacuum tube).
Insert the needle into the patient’s vein.
Push the tube into the holder to pierce the rubber stopper; blood will automatically flow into the tube due to vacuum pressure.
Allow the tube to fill to its pre-determined volume.
Gently invert the tube several times if additives are present (do not shake).
Label the tube and send for laboratory analysis following standard protocols.
Laboratory Blood Sample Test Vacuum Blood Collection Tube
The Vacuum Blood Collection Tube is a sterile, pre-evacuated container designed for the direct collection of blood samples. Utilizing controlled negative pressure, it enables the automatic draw of a precise blood volume, ensuring standardized sample collection for a wide range of clinical laboratory tests.
Structure and Components:
Tube Body: Manufactured from durable, medical-grade materials such as polyethylene terephthalate (PET), offering excellent chemical resistance and sample visibility.
Pre-set Vacuum: The tube is pre-filled with a specific vacuum pressure to draw the exact required volume of blood.
Color-coded Stopper/Cap: The rubber stopper is color-coded to indicate the presence and type of additive (e.g., EDTA, citrate, heparin, clot activator) and the tube’s intended use.
Additives (Optional): Tubes may contain anticoagulants, clot activators, serum separators, or no additives, depending on the test requirements.
Label: Clearly printed for patient identification, additive details, and compatibility with barcode systems.
Features:
Accurate volume collection: Ensures consistent and reliable blood volumes.
Sterile and single-use: Minimizes risk of cross-contamination.
Color-coded caps: Easy identification of tube type and corresponding laboratory test.
Leak-proof design: Guarantees safe sample handling and transport.
Available with different additives: To support diverse testing needs, including coagulation, chemistry, hematology, serology, and molecular diagnostics.
Specifications:
Model/Name | Size | Color | Additives | |||
CNME100101-1A | Plain Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Red | NO |
CNME100101-2A | Clot Activator Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Red | Clot Activator |
CNME100101-3A | Heparin Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Green | Sodium/Heparin lithium |
CNME100101-4A | Gel&clot Activator Tube | 1-4ml (13*75mm) | 4-6ml (13* 100mm) | 6-9ml (16*100mm) | Yellow | Gel&clot Activator |
CNME100101-5A | Glucose Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Grey | EDTA+Sodium Fluoride |
CNME100101-6A | EDTA Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Purple | EDTA K2(K3/Na2) |
CNME100101-7A | ESR Tube | 1-5ml (13*75mm) | / | / | Black | 3.8%Sodium Citrate |
CNME100101-8A | PT Tube | 1-5ml (13*75mm) | 5-7ml (13* 100mm) | 7-10ml (16*100mm) | Blue | 3.2% Sodium Citrate |
Advantages:
Efficient and fast collection: No need for syringe transfer; reduces collection time and minimizes sample handling errors.
Standardized sampling: Pre-calibrated vacuum ensures consistency across samples.
Improves workflow: Supports high-throughput environments like hospitals, clinics, and diagnostic labs.
Enhanced safety: Closed system reduces the risk of exposure to bloodborne pathogens.
Wide compatibility: Suitable for use with standard phlebotomy systems, such as multi-sample needles and holders.
Usage Instructions:
Assemble the collection device (needle, holder, and vacuum tube).
Insert the needle into the patient’s vein.
Push the tube into the holder to pierce the rubber stopper; blood will automatically flow into the tube due to vacuum pressure.
Allow the tube to fill to its pre-determined volume.
Gently invert the tube several times if additives are present (do not shake).
Label the tube and send for laboratory analysis following standard protocols.