CNME070452
CNMEDITECH
Handheld LCD SpO2 Oxygen Saturation Monitor Fingertip Pulse Oximeter for Adult/Pediatric/Neonate Patients
Description:
The CNME070452 is a Handheld Pulse Oximeter consisting pulse oximetry and pulse rate analysis which is designed to provide fast and reliable measurements of oxygen saturation(SPO2) and Pulse Rate (PR). It is a portable device for spot-checking, monitoring of adult, pediatric and neonate patients.It can be used in the hospital, clinical environment, daily household monitoring and during transportation.
Feature:
3.5 inch high resolution color LCD monitor.
Two types of power supply: AC Adaptor or lithium battery.
Three measurement modes: spot-checking,monitoring and recording.
Data can be stored on the computer and managed, analyzed and printed with a data analysis system.
Mute sleep monitoring with data storage and automatic energy-saving functions, automatic shutdown after five minutes of non-use.
Three levels visual and audible alarm and the alarm ranges are adjustable.
Specifications:
Weight | 265g Weight(with batteries installed) |
Dimensions | 80mmWx160mmHx30mmD (3.1in.Wx6.3in.Hx1.2in.D) |
Screen size | 88.9mm(3.5in.), measured diagonally |
Screen type | TFT-LCD, white LED backlight |
Resolution | 320x480 pixels |
Categories | Patient status and system status |
Priorities | Low,medium,and high |
Notification | Audible and visual |
Setting | Full storage,low battery and sensor off etc. |
Alarm volume level | 45 to 85 decibels |
Alarm system delay | <10seconds |
Measurement range | 0% to 100% |
Accuracy | 70-100% (±2%), <70% undefined |
Resolution | 1% |
Display wave speed | 10.00 mm/sec |
PR range | 25bpm to 350bpm |
Accuracy | ±2bpm/±2% take maximum |
Resolution | 1bpm |
Battery | Lithium-lon batteries with 4,400mAh will typically provide 15 hours of monitoring |
Type | Lithium-lon Battery |
Voltage | 3.7V |
Transport and Storage Temperature | −20℃ to 55℃ (−4℉ to 131℉ ) |
Operating Conditions Temperature | 5℃ to 40℃ ( 41℉ to 104℉ ) |
Atmospheric Pressure | 700hPa to 1060hPa |
Relative humidity | 0 % to 95 % non condensing |
Standard | Pulse Oximeter, Adult finger clip SpO2 sensor, Lithium battery, power adapter |
Optional | Various SpO2 sensors, Data analysis software |
Memory | A trend chart can be formed based on the monitoring data of the last half hour and updated in real time. |
Tabular format | One table for all parameters |
Product details:
Package details:
25pcs/ctn,72*45*55cm,G.W.:26kg.
Handheld LCD SpO2 Oxygen Saturation Monitor Fingertip Pulse Oximeter for Adult/Pediatric/Neonate Patients
Description:
The CNME070452 is a Handheld Pulse Oximeter consisting pulse oximetry and pulse rate analysis which is designed to provide fast and reliable measurements of oxygen saturation(SPO2) and Pulse Rate (PR). It is a portable device for spot-checking, monitoring of adult, pediatric and neonate patients.It can be used in the hospital, clinical environment, daily household monitoring and during transportation.
Feature:
3.5 inch high resolution color LCD monitor.
Two types of power supply: AC Adaptor or lithium battery.
Three measurement modes: spot-checking,monitoring and recording.
Data can be stored on the computer and managed, analyzed and printed with a data analysis system.
Mute sleep monitoring with data storage and automatic energy-saving functions, automatic shutdown after five minutes of non-use.
Three levels visual and audible alarm and the alarm ranges are adjustable.
Specifications:
Weight | 265g Weight(with batteries installed) |
Dimensions | 80mmWx160mmHx30mmD (3.1in.Wx6.3in.Hx1.2in.D) |
Screen size | 88.9mm(3.5in.), measured diagonally |
Screen type | TFT-LCD, white LED backlight |
Resolution | 320x480 pixels |
Categories | Patient status and system status |
Priorities | Low,medium,and high |
Notification | Audible and visual |
Setting | Full storage,low battery and sensor off etc. |
Alarm volume level | 45 to 85 decibels |
Alarm system delay | <10seconds |
Measurement range | 0% to 100% |
Accuracy | 70-100% (±2%), <70% undefined |
Resolution | 1% |
Display wave speed | 10.00 mm/sec |
PR range | 25bpm to 350bpm |
Accuracy | ±2bpm/±2% take maximum |
Resolution | 1bpm |
Battery | Lithium-lon batteries with 4,400mAh will typically provide 15 hours of monitoring |
Type | Lithium-lon Battery |
Voltage | 3.7V |
Transport and Storage Temperature | −20℃ to 55℃ (−4℉ to 131℉ ) |
Operating Conditions Temperature | 5℃ to 40℃ ( 41℉ to 104℉ ) |
Atmospheric Pressure | 700hPa to 1060hPa |
Relative humidity | 0 % to 95 % non condensing |
Standard | Pulse Oximeter, Adult finger clip SpO2 sensor, Lithium battery, power adapter |
Optional | Various SpO2 sensors, Data analysis software |
Memory | A trend chart can be formed based on the monitoring data of the last half hour and updated in real time. |
Tabular format | One table for all parameters |
Product details:
Package details:
25pcs/ctn,72*45*55cm,G.W.:26kg.